Silfradent Arkiv - Puremed - Professional Tissue Regeneration based on pure biology https://www.puremed.dk/vare-tag/silfradent/ Bio-logic Tissue Regeneration for surgeons and healthcare professionals Sun, 17 Sep 2023 01:35:47 +0000 en-US hourly 1 https://www.puremed.dk/wp-content/uploads/2023/01/cropped-Tegnebraet-Puremed-label-32x32.png Silfradent Arkiv - Puremed - Professional Tissue Regeneration based on pure biology https://www.puremed.dk/vare-tag/silfradent/ 32 32 Medifuge Centrifuge https://www.puremed.dk/vare/medifuge/ Sun, 08 Jan 2023 14:34:08 +0000 http://puremed.dk/?post_type=product&p=19006 [:da]

Medifuge Centrifuge

Blood Phase Separator
The medical device MEDIFUGE CGF allows for the use of up to 8 test tubes for the creation of CGF (fibrin);

  • A microprocessor control system allows for the maintaining of a constant speed;
  • The exception rotor system with self-ventilation protects the blood sample from heat exposure. The rotor-holding compartment, the lid, and the test tube holders guarantee biological safety in terms of bio-containment, in the event of test tube breakage;
  • The test tube holders and rotor are built from thermal, antistatic material that is easy to clean, extract and sterilize in an autoclave at 135°;
  • MEDIFUGE CGF is equipped with a decontamination cycle with UVC reflected light;
  • Cycle duration 5 minutes at 1,000 revs;
  • The electronic control engine and its internal parts require no maintenance;
  • Noise levels fall below the standards required and do not exceed 57 dBa.

Technical features

  • Power source: 230V+/-10% | 50/60 Hz
    100-115V  50/ 60 Hz;
  • Nominal power consumption: 120 VA;
  • Weight: 9,4 Kg;
  • Dimensions: WxDxH: cm 28x32x24.

[:en]

Medifuge Centrifuge

Blood Phase Separator
The medical device MEDIFUGE CGF allows for the use of up to 8 test tubes for the creation of CGF (fibrin);

  • A microprocessor control system allows for the maintaining of a constant speed;
  • The exception rotor system with self-ventilation protects the blood sample from heat exposure. The rotor-holding compartment, the lid, and the test tube holders guarantee biological safety in terms of bio-containment, in the event of test tube breakage;
  • The test tube holders and rotor are built from thermal, antistatic material that is easy to clean, extract and sterilize in an autoclave at 135°;
  • MEDIFUGE CGF is equipped with a decontamination cycle with UVC reflected light;
  • Cycle duration 5 minutes at 1,000 revs;
  • The electronic control engine and its internal parts require no maintenance;
  • Noise levels fall below the standards required and do not exceed 57 dBa.

Technical features

  • Power source: 230V+/-10% | 50/60 Hz
    100-115V  50/ 60 Hz;
  • Nominal power consumption: 120 VA;
  • Weight: 9,4 Kg;
  • Dimensions: WxDxH: cm 28x32x24.

[:]